SECTIONS
EDITIONS
NETWORK
AIXX Pedia The encyclopedia of compute hardware

AIXX Pedia › Model Entry › B200

Official NVIDIA Blackwell rack scene image (vendor image)
Deployment Scenarios · AIXX Pedia (NVIDIA official website)

B200

NVIDIA Blackwell First-Gen Flagship · GB200 Core · Model Entry #013

Overview OVERVIEW

B200 Is NVIDIA Blackwell architecture's first-gen flagship GPU Announced at GTC on March 18, 2024 — 18 PFLOPS FP4 per card (sparse) / 9 PFLOPS (dense), 192GB HBM3e memory (launch spec), NVLink 5 · 1.8TB/s, and HGX configurations rated up to 1000W TDP (per the current official NVIDIA Blackwell datasheet[1]). It is core of the GB200 NVL72 rack : 72 B200s + 36 Grace CPUs per rack (based on the GB200 = 1 Grace + 2 B200 superchip figure[1]).

Memory must be stated honestly across three figures: launch figure 192GB ; the current official datasheet lists HGX B200 version at 180GB/7.7TB/s ; GB200 version at 186GB/8TB/s — Three Official Figures Coexist in official documentation; procurement contracts should specify the exact product line (per the current datasheet[1]). Volume production ramped in February 2025 (Q4 FY25 earnings cited "billions of dollars in the first quarter"[4]), and after the GB300 generation (Blackwell Ultra) took over, B200 entered large-scale installed-base deployment.

The current China export control situation must be made clear: B200 is not on the approved list for China — The B30A (China-market Variant proposal) was not approved in 2025 (per public reporting[6]); the new BIS rules of 2026-01-15 only cleared the H200 and below tiers, and B200 remains off the list (original rule documents verified[7]). This entry records the policy facts as stated and does not constitute legal advice.

Use Cases FIT

AIXX Index (0–100): estimated in this library by weighting public specs — compute 40% + interconnect 30% + ecosystem 30%.

Trillion-Parameter Training Cluster 95AIXX Index
The GB200 NVL72's 72-GPU single NVLink domain — the rack-level core solution for trillion-parameter MoE training (per operational deployments).
FP4 Inference Factory 93AIXX Index
9 PFLOPS dense FP4 per card — the high-throughput foundation of inference factories; the 8-card HGX B200 delivers 72 PFLOPS per node (144 sparse).
HPC / FP64 72AIXX Index
FP64 Tensor 37 TFLOPS (datasheet figure) — improved over Hopper but not the FP4 headline; weigh carefully for double-precision-heavy workloads.
China-market New Procurement 20AIXX Index
B200 is not on the China-approved list (per BIS rules[7]) — no new channels in mainland China carry this model; spot units fall into the installed base and the grey-market.

History HISTORY

On March 18, 2024 , the Blackwell platform was announced at GTC: the B200 was revealed as the first-generation flagship GPU, with the HGX B200 baseboard defined alongside — introduced together with the GB200 superchip (1 Grace + 2 B200) and the GB200 NVL72 rack (per GTC announcements and the official datasheet[1][3]).

In February 2025 , the production ramp: NVIDIA's Q4 FY25 earnings disclosed that Blackwell contributed "billions of dollars" in revenue in its first quarter (per the earnings report[4]) — a faster path from launch to scaled revenue than any prior generation, driven by AI factory buildout demand.

2025 , the B300 generation takes over: Blackwell Ultra (B300) was announced — per the current official comparison table: B300 delivers 108 dense NVFP4 PFLOPS vs. 72 for the B200, 288GB memory vs. the 192GB tier, and a major FP64 repositioning (per the current datasheet comparison[1]) — both generations will coexist in the market through 2026.

China Export Control Line : B200 was never on the China-approved list — the B30A China-market Variant proposal went unapproved in 2025 (per public reporting[6]); the new BIS rules of 2026-01-15 only cleared the H200 and below tiers (original rules verified[7]). B200 circulation in the mainland market falls into non-compliant and grey-market territory (per public reporting); this database does not constitute legal advice.

Technical Specifications SPECIFICATIONS

ItemSpecs (NVIDIA B200 · per current official datasheet, product-line splits noted)
ArchitectureNVIDIA Blackwell
FP4 Compute18 PFLOPS per card (sparse) / 9 PFLOPS (dense) · HGX total 144 / 72
FP64 Tensor Core37 TFLOPS (datasheet figure)
Memory (three figures, stated honestly)Launch figure 192GB HBM3e · HGX B200 current version 180GB/7.7TB/s · GB200 version 186GB/8TB/s[1]
InterconnectNVLink 5 · 1.8TB/s per card · PCIe Gen5
PowerHGX version configurable up to 1000W · GB200 version 1200W (configurable ceiling figure)
Superchip RelationshipGB200 = 1× Grace + 2× B200 (NVLink-C2C packaging)
Main System Form FactorsHGX B200 8-card baseboard · GB200 NVL72 rack · GB200 NVL4
Launch / Volume ProductionAnnounced at GTC on 2024-03-18 · Production ramp February 2025 (per earnings report[4])

Specs per the current official NVIDIA Blackwell datasheet (rev 4204213.Oct25, C5 official snapshot[1]); Three Official Figures Coexist for memory capacity in official documentation — contracts should specify the exact product line.

B200 · BlackwellFP4 dense 9 PFLOPS · 192GB-class B300 · Blackwell UltraNVFP4 dense 108 · 288GB Blackwell Two-Generation Comparison (per current NVIDIA official datasheet)

Blackwell Two-Generation Comparison TWO GENERATIONS

ItemB200(Blackwell)B300(Blackwell Ultra)
NVFP4 dense72 PFLOPS108 PFLOPS
Memory192GB-class HBM3e (three figures)288GB HBM3e
FP64296 TFLOPS (TC figure)10 TFLOPS (officially and substantially revised)
Rack Form FactorGB200 NVL72GB300 NVL72
One-line buying adviceInstalled-base deployment mainstayFlagship of new rack sales

Figures per the current datasheet[1]; see the B300 entry for details — the large FP64 gap between the two generations is a deliberate official architectural trade-off (per public statements); note this for HPC selection.

Family Members FAMILY

The Blackwell family is tiered by form factor; B200 is the first-gen flagship, with family members as follows:

B200 (Blackwell first-gen flagship · GB200 core card · this entry)GB200 superchip (1 Grace + 2 B200 · NVL72 core)HGX B200 8-card baseboard (air-cooled/liquid-cooled system form factors)B300 (Blackwell Ultra · see entry)GB300 NVL72 (B300 rack · see entry)

Cooling & Deployment COOLING

B200 deploys in two form factors: HGX B200 8-card baseboard (air-cooled/liquid-cooled systems, configurable up to 1000W per card — rack power budgeting per as-shipped configuration) and the GB200 superchip rack (NVL72 fully liquid-cooled, 36 Grace + 72 B200 + 9 NVLink switch trays). The ~1000W Board Power (TBP/TGP) means even air-cooled 8-card systems sit at the edge of rack cooling density — liquid cooling support (CDU loops, see the liquid-cooled CDU entry) is mandatory, not optional, in high-density deployments.

The three GB200 rack deployment essentials: full liquid cooling loop chain (primary/secondary side), full NVLink domain verification (copper backplane + switch trays), and power busbar (1400A-class figure, see the GB200 entry's six-part stress test) — B200 procurement discipline is shared with the GB200 entry.

Model Compatibility MODEL FIT

Model / ScenarioGB200 NVL72 figures (72×B200)AIXX Index
Trillion-Parameter MoE Training72-GPU single NVLink domain + 13.4TB HBM3e pool — fabric only across racks95
FP4 Inference Factory9 PFLOPS dense FP4 per card × 72 — the throughput flagship of inference factories93
FP64 HPC37 TFLOPS TC per card — usable but not the headline (compare B300's major FP64 revision)72
China-market New DeploymentNot on the approved list — not applicable to new mainland China channels (per BIS rules[7])—

Figures from the GB200 NVL72 entry and datasheet[1]; not a performance guarantee.

Official NVIDIA Blackwell rack scene image
NVIDIA Blackwell rack scenario (official image · NVIDIA website; B200 product image pending)

Software & Ecosystem ECOSYSTEM

ItemRequirements / Status
CUDABlackwell generation (compute capability 10.x-class, per official table) — CUDA 12.8+ supports Blackwell (per public figures)
FP4 stackFP4/NVFP4 precision is natively supported by the Tensor Core and CUDA stack (per datasheet[1])
Collective CommunicationNCCL auto-detects the NVLink 5 domain — full-width interconnect within the rack
Rack softwareGB200 systems run the Base Command/AI Enterprise stack (same as GB200 entry)
System VendorHGX B200 baseboard: Dell/Supermicro/Lenovo, among others (per each vendor's product line)

Software versions evolve over time; NVIDIA official releases prevail.

Purchasing & Inspection PROCUREMENT

Key inspection points for B200-related procurement (three items):

1
Memory figures vs contract
192/180/186GB — three figures coexist; the procurement contract must specify the product line (HGX version/GB200 version) and the datasheet-figure capacity, verified on arrival via nvidia-smi measurements.
2
Power configuration budgeting
HGX version configurable up to 1000W/card, GB200 version 1200W — cross-check as-shipped power tier against facility planning; "configurable ceiling" is not "default value."
3
Compliance status first
B200 is not on the China-approved list (per BIS rules[7]) — B200 circulation through mainland China channels is grey-market; assess compliance risk upfront; this database does not constitute legal advice.

Acceptance Quick Reference QUICK CHECK

B200 Four-Step Quick Check (run alongside GB200/HGX system acceptance):

1
Identity and memory figures
nvidia-smi: B200 model, memory capacity (180/186/192GB per product line) — item-by-item match against the contract figures.
2
FP4 baseline
Measured FP4 dense 9 PFLOPS-tier benchmark (≥80% considered Pass, per estimation methodology) — Blackwell's headline precision must be measured.
3
NVLink 5 domain
1.8TB/s/card tier nvlink status full-port check — GB200 racks accepted as a full NVLink domain chain (same as GB200 entry).
4
Power tier Burn-in Test
Full Load burn-in per as-shipped power configuration: stable temperatures, zero ECC growth (per case-law framework).

Shipping & Delivery LOGISTICS

1
Cross-Border Circulation Compliance (hard gate)
B200 is not on the China-approved list (per the BIS rules of 2026-01-15[7]) — no compliant new procurement path exists through mainland channels; compliance risk for related purchases must be assessed upfront; statements in this database do not constitute legal advice.

Glossary Cards GLOSSARY

Blackwell Gen 1 vs Ultra

Two generations: B200 (Blackwell) and B300 (Blackwell Ultra): Ultra lifts dense NVFP4 throughput by 50% (72→108 PFLOPS), 288GB memory, and a major FP64 repositioning (296→10 TFLOPS, an official trade-off) — both generations circulate in parallel (per the current datasheet comparison[1]).

Three memory specs

Three official figures for B200 memory: 192GB at launch, 180GB/7.7TB/s in the current HGX revision, and 186GB/8TB/s for the GB200 version (per datasheet[1]) — labeling differs by product line; state the product line explicitly in procurement contracts.

B30A and the approved list

The B30A was a China-market Variant proposal (per public reporting) and was not approved; the BIS rules of 2026-01-15 only cleared the H200 and below — neither B200 nor B300 is on the approved list (rule text verified[7]).

Limitations & Controversies LIMITS

  • Hard compliance gate for China-market sales : B200 is not on the China-approved list (per BIS rules[7]) — no compliant path exists for new mainland China channels; compliance risk for related circulation must be assessed upfront; this database does not constitute legal advice.
  • Contract risk of the three memory specs : 192/180/186GB coexist (per datasheet[1]) — if the contract does not specify the product line, disputes at delivery are guaranteed.
  • Management cost of configurable power : 1000W/1200W configurable caps—a power tier with an open ceiling demands significant planning flexibility in facility power and cooling (datasheet basis).
  • FP64 and the B300 trade-off : B300 officially makes a major FP64 adjustment (10 TFLOPS basis)—the FP64 strategy gap between the two Blackwell generations itself shows that FP64 in data center GPUs is ceding ground to AI precision (public basis). HPC buyers should take note when selecting.
  • Residual value and circulation : The residual value curve of B200 racks and HGX units after GB300 ramp—supported by deployed fleet size rather than new-unit scarcity (compiled by this database).

Market Notes MARKET NOTE

B200 · Market band not yet open

B200 circulates as full racks and HGX systems, with a special compliance status in mainland channels— AIXX Pedia honesty principle: no market band; prices are subject to the seller's quote (rack-level pricing follows the GB200 NVL72 entry).

Spot search: AIXX Exchange Hall › (Zero-commission Matching, hence neutral data).

FAQ FAQ

B200 or B300—how to choose?

For new rack deployments, choose B300 (108 PFLOPS NVFP4 dense / 288GB); for existing deployments and specific FP64 needs, look at B200—note that B300 officially made a major FP64 adjustment (10 TFLOPS basis), which HPC buyers should double-check.

How much memory does B200 actually have?

Three official figures coexist: 192GB at launch, 180GB/7.7TB/s in the current HGX version, 186GB/8TB/s in the GB200 version (datasheet basis)—specify the exact product line in the purchase contract and verify on arrival.

Can you buy a B200 in mainland China?

B200 is not on the China-approved list (BIS 2026-01-15 rule basis)—there is no compliant path through legitimate new-supply channels; circulation falls into a grey-market. Assess compliance risk up front; this database does not constitute legal advice.

HGX B200 system or GB200 NVL72—how to choose?

The dividing line is scale and facility: 8-GPU HGX systems (Air-cooled deployable) suit clusters of dozens of GPUs; NVL72 full racks (single 72-GPU domain + Liquid-cooled retrofit) suit AI-factory scale—see the GB200 NVL72 and HGX platform entries for both tiers.

What to test at B200 acceptance?

Four steps: verify memory against the contract (180/186/192GB by product line) → baseline FP4 dense at the 9 PFLOPS tier (≥80% Pass, estimated basis) → check all NVLink 5 domain ports → Burn-in Test at the delivered power tier. For GB200 rack form, add full-chain Liquid-cooled and NVLink domain acceptance (same as the GB200 entry).

B300GB200 NVL72GB300 NVL72HGX B300 NVL16Grace CPUCUDABlackwell platformThree memory specsChina-approved list

Model comparison and selection COMPARE

References REFERENCES

  1. NVIDIA official — NVIDIA Blackwell Datasheet (4204213.Oct25 rev: GB200 NVL72/NVL4/HGX B200 three-column specs, official C5 snapshot) https://www.nvidia.com/en-us/data-center/hgx/
  2. NVIDIA website — GB200 NVL72 product page (superchip relationship) https://www.nvidia.com/en-us/data-center/gb200-nvl72/
  3. NVIDIA Newsroom — Q4 FY25 earnings (Blackwell production ramp) https://nvidianews.nvidia.com/
  4. Institute for Progress — analysis of the B30A China-market Variant proposal (public reporting basis) https://ifp.org/
  5. BIS export control rule (2026-01-15, H200 and below approved, verified against rule text) https://www.federalregister.gov/
  6. Listing search — AIXX Exchange (Zero-commission Matching; no market snapshot for B200 yet, actual price subject to the seller's quote) https://www.aixx.vip/hall.html?model=B200
Versions and errata | This entry is maintained by the AIXX Pedia editorial team, AI-assisted drafting with human fact-checking. Updated 2026-10-10 · Version v1.0 · All changes tracked and auditable. Spotted an error? Let us know via Corrections Channel ; corrections are published after verification and recorded in version history.

Video Overview VIDEO

This Library
Editorial PolicyAbout This Library (Disclosure of Interests)Corrections Channel
Editorial Constitution Summary
Every claim sourcedDrawbacks always stated · corrections publicly loggedNo paid entries acceptedZero traffic-funneling or sales elements within entriesMarket data attached only as data modules
AIXX Family
AIXX PediaAIXX ExchangeAIXX News
Market overview: AIXX Exchange · © 2026 AIXX Pedia · An AIXX Product