Spec Card SPEC CARD
NVIDIA B300 (Blackwell Ultra GPU)
One B300 = the Blackwell Ultra GPU die itself, i.e. each chip on the HGX B300 NVL16 8-GPU board: 288GB HBM3e in a single package (1.5x the B200 launch figure / 1.6x current HGX), peak FP4 of 20 sparse | 15 dense PFLOPS per GPU (dense up 50% over B200), TGP 1400W, NVLink 1.8TB/s, PCIe Gen6; the trade-offs are INT8 cut to 1/24 and FP64 to 1/30 — a card squarely aimed at pure AI inference factories. Announced at GTC on 2025-03-18, shipping from H2 2025, the spot-market generation of 2026; for used/spot inquiries, align on 288GB HBM3e per card for this GPU; superchips with a Grace CPU belong to the GB300 card entry, and the 8-GPU board-level system belongs to the HGX B300 NVL16 entry
Overview
The NVIDIA B300 is a data center GPU based on the Blackwell Ultra architecture, a dual-die design integrated in a single package, built on TSMC's 4NP process with roughly 208B transistors, featuring 160 SMs and 640 fifth-generation Tensor Cores. Memory is 288GB of HBM3e with a total bus width of 8192-bit; at peak configuration, FP4 throughput is 20 PFLOPS sparse and 15 PFLOPS dense, roughly a 50% dense uplift over the previous Blackwell generation. Interconnect is NVLink, with 18 links per direction and 1.8TB/s bidirectional GPU-to-GPU bandwidth, plus PCIe Gen6 support. TGP tops out at 1400W. Positioned for large-scale FP4 AI inference and training clusters, it is the core compute unit of the HGX B300 NVL16 8-GPU board and the GB300 superchip.
Core Specs
| Architecture | NVIDIA Blackwell Ultra (Ultra tier of the Blackwell architecture, pure GPU without a Grace CPU) — each B300 is built on TSMC 4NP with 208 billion transistors, a dual-die single GPU (official blog states 'TSMC 4NP and features 208B transistors' and 'Dies per GPU: 2'); up to 160 SMs per GPU organized into 8 GPCs, 640 fifth-generation Tensor Cores (per the official blog); attention engine at 10.7 TeraExponentials/s, officially '2x higher attention performance' versus Blackwell (blog Table 2 and the NVL72 page) |
| Memory | 288GB HBM3e per package (primary value: official blog Table 2 '288 GB HBM3E' plus DGX B300 user guide '8 x 288 GB = 2.3 TB total'); two baselines coexist versus the B200 — against the 192GB launch figure it is 1.5x (blog Table 2 lists '192 GB | 288 GB', NVL72 page says '1.5x larger HBM3E'), and against HGX's current 180GB it is 1.6x (Lenovo quote: '288 GB...compared with 180 GB on the B200'); board-level HGX B300 total is 2.1TB; usable capacity figures: 279GB (datasheet search snippet) / 268GB (corroborating-level note) |
| Memory Type | HBM3e (12-Hi stacks; official blog correction note dated 9/24/25: 'proper 12 HBM stacks instead of 8' — the residual 'Eight 12-Hi stacks' in the body is a known inconsistency; take the corrected 12 stacks, consistent with 288GB = 12 x 24GB per stack) |
| Memory Bus Width | 8,192-bit (official blog HBM configuration verbatim: '16 × 512-bit controllers (8,192-bit total width)') |
| Memory Bandwidth | 8TB/s per GPU (official blog: '8 TB/s per GPU, 2.4x improvement over H100'; cross-checked: rack 576TB/s ÷ 72 = 8TB/s) |
| Compute | Peak per-GPU figures (primary values): FP4 (NVFP4) TC 20 PFLOPS sparse | 15 PFLOPS dense (official blog Table 2 '15 | 20 PetaFLOPS', cross-checked against rack 1440|1080 ÷ 72; dense is 1.5x Blackwell's 10, sparse 20 unchanged); FP8/FP6 TC 10 sparse | 5 dense (blog '5 | 10 PetaFLOPS'); INT8 TC roughly 375 TOPS sparse (HGX board 3 POPS ÷ 8, a 24x generational cut versus the B200's 9000 TOPS per card); FP16/BF16 TC 4.5 sparse | 2.25 dense (HGX 36 ÷ 8); TF32 TC 2.25 sparse (HGX 18 ÷ 8); FP32 75 TFLOPS (HGX 600 ÷ 8); FP64/FP64 TC 1.25 TFLOPS (HGX 10 ÷ 8, roughly a 30x cut versus B200's 37 — Ultra traded Tensor Core area for dense FP4). HGX B300 board-level reduced-power tier per GPU: FP4 18|13.5 (144|108 ÷ 8, officially confirmed); do not mix with the peak tier |
| Power | TGP up to 1400W (official blog Table 2: 'Max power (TGP): Up to 1,400W', versus Blackwell 1200W and Hopper 700W); HGX B300 ships a reduced-power board SKU at roughly 1100W (IntuitionLabs/Lenovo SR680a V4 search-quote level, not official per-card confirmation, note only); DGX B300 8-GPU system draws 14.5kW |
| Interconnect | NVLink 5th gen, 1.8TB/s bidirectional per GPU (official blog: '1.8 TB/s bidirectional (18 links x 100 GB/s)', HGX page: 'GPU-to-GPU 1.8 TB/s'); HGX B300 8-GPU all-to-all totals 14.4TB/s, with two boards bridged into an NVL16 domain; PCIe Gen6 x16 is 256GB/s bidirectional (blog Table 1 '256 (Gen 6)', double Hopper's Gen5 128GB/s); networking: HGX B300 is provisioned with 1.6TB/s, DGX B300 with ConnectX-8 at 800Gb/s per GPU |
| Launch Year | 2025 (announced at GTC on 2025-03-18, per official press release; 'expected to be available from partners starting from the second half of 2025' per official shipping language; official HGX page footnote 'shipping now' and NVL72 page 'Available Now' confirm the spot-market generation) |
| SM and CUDA cores | Up to 160 SMs / 640 fifth-generation Tensor Cores (official blog: '160 Streaming Multiprocessors (SMs) across two dies, providing 640 fifth-generation Tensor Cores', footnote 'up to 160 SMs'); each SM has 128 CUDA cores + 4 Tensor Cores + 256KB TMEM (per the blog); 20,480 CUDA cores total (160 x 128, derived); SM count is +11% versus the original Blackwell's 144 and +21% versus Hopper's 132 |
| L2 cache | Not covered |
| Confidential Computing | Not covered (no confidential computing entries surfaced in this round of B300 source verification — better to omit than invent; Blackwell-generation confidential computing is directly confirmed in the B200 GTC 2024 press release, for verification in the full entry) |
| Codecs | Not covered (no codec count entries for the B300 found in current official sources — better to omit than invent) |
| MIG Slicing | Not covered |
| Form Factor | SXM module (Blackwell Ultra SXM, per official HGX page Form Factor) — deployment forms: HGX B300 NVL16 8-GPU board (air- or liquid-cooled, the OEM system vendors' shipping form; this card's position) / DGX B300 8-GPU system at 14.5kW / GB300 NVL72 rack with 72 GPUs, fully liquid-cooled (pure-GPU view; superchips with a Grace CPU belong to the GB300 card entry) |
Specs verified against official documentation (
official benchmarks , updated 2026-10-10) · actual price subject to the seller's quote
Use Cases
- Hyperscale LLM inference serving: 288GB HBM3e per card is well suited to hosting long-context, large-parameter models, with FP4 NVFP4 as its peak throughput tier; officially, attention performance is said to have doubled over the previous Blackwell generation
- Large-model training and post-training (SFT/RLHF): 10 PFLOPS of dense FP8 per card combined with NVLink's 1.8TB/s bidirectional interconnect suits multi-node, multi-GPU scaled training clusters
- HGX B300 NVL16 8-GPU board-level deployment: the single card is the standard building block of the 8-GPU SXM board, matching the board's total 2.1TB memory figure, aimed at rack-scale AI factory buildouts
- GB300 NVL72 rack and DGX B300 system composition: as the underlying GPU component of the Grace-CPU superchip and 8-GPU systems, for end-to-end AI infrastructure procurement and compute accounting
Same-Family Models
| Model | Memory | Power |
|---|
| NVIDIA T4 Compare | 16GB GDDR6 with ECC (enabled by default) | 70W (total board power, default) |
| NVIDIA A100 Compare | Dual versions: 40GB HBM2 / 80GB HBM2e (80GB added at SC20 on 2020-11-16), with ECC | SXM4 400W (same for 40GB/80GB); PCIe version 250W for 40GB / 300W for 80GB |
| NVIDIA H20 Compare | 96GB HBM3 (consistent across Flopper, VipraTech, and Tencent News sources) | 400W TDP (three sources: Flopper, VipraTech spec sheet, and Tencent News' "400W thermal design power"; VipraTech's body text also cites 350W, a conflicting figure that has been discarded) |
| NVIDIA GB300 Compare | 288GB HBM3e (per GPU package; 576GB for the superchip; HGX board-level 2.1TB / rack-level 20TB coexist) | TGP up to 1400W |
| NVIDIA A30 Compare | 24 GB HBM2 | 165 W |
| NVIDIA GeForce RTX 4090 Compare | 24GB GDDR6X | 450W TGP (315W average gaming, 850W recommended system power) |
Video Overview VIDEO
Procurement & Inspection Notes
- Power and supply: this card's TGP tops out at 1400W, well above the previous Blackwell's 1200W and Hopper's 700W; a full DGX B300 8-GPU system draws 14.5kW and ships with twelve 3.2kW power supplies, so rack power redundancy and liquid-cooling capacity must be budgeted in advance; there is also a roughly 1100W reduced-power HGX deployment SKU — confirm the power tier when requesting quotes
- Verifying performance tiers: the same B300 comes in a peak tier (FP4 20 sparse, 15 dense PFLOPS) and an HGX board-level reduced-power tier (FP4 18 sparse, 13.5 dense PFLOPS per GPU). Contracts and acceptance sheets should clearly state the performance and power tier of the SKU purchased, to avoid confusing board-level figures with single-card peak figures
- Memory and interconnect inspection: for spot/used units, align on the physical 288GB HBM3e per card (a conservative 2.1TB board-level total also exists for HGX); usable capacity below the physical figure is normal; verifying NVLink's 1.8TB/s bidirectional interconnect requires the 8-GPU SXM form factor and companion baseboard — non-SXM versions cannot achieve that bandwidth; PCIe is Gen6, so motherboards and switches must match
- Clarifying procurement scope: superchips with a Grace CPU belong to the GB300 card scope, 8-GPU board systems to the HGX B300 NVL16 scope; when quoting for a single GPU, make clear which physical form the seller's price corresponds to, to prevent scope mismatches
- Architectural trade-off awareness: this generation cuts INT8 throughput sharply versus the previous board generation (72 → 3 POPS), and FP64 also drops to 10 TFLOPS at board level; if existing workloads depend on INT8 Quantization stacks or FP64 HPC compute, assess compatibility before purchasing
FAQ
Is the B300's 288GB memory a single-card figure? How does it differ from the HGX B300 board's 2.1TB?
288GB is the physical HBM3e capacity within a single B300 GPU package, made up of twelve 12-Hi HBM stacks. The HGX B300 NVL16 8-GPU board's Total Memory is rated at 2.1TB — a board-level total on a conservative basis of roughly 262GB per card, which differs slightly from 8 x 288GB = 2.3TB (the DGX B300 figure); actual usable capacity is also below physical. When comparing purchases, distinguish between per-card physical capacity, board-level rated capacity, and usable capacity.
What does the B300 improve over the B200? Is FP4 throughput doubled?
No, it is not doubled. Per official figures, B300 dense FP4 is 15 PFLOPS, up 50% from the B200's 10 PFLOPS; sparse FP4 is unchanged at 20 PFLOPS for both. On memory, 288GB is 1.5x the B200's 192GB launch figure. The official '2x' refers to attention performance, not total FP4 throughput. Note also that B300's INT8 and FP64 throughput shrink substantially versus the B200 — a deliberate design trade-off in Blackwell Ultra that shifts Tensor Core resources toward FP4.
What should I watch for when buying a B300 server? How do I tell the peak tier from the reduced-power tier?
Confirm three things: first, power and cooling — a single card's TGP tops out at 1400W and a full 8-GPU system like the DGX B300 draws 14.5kW, typically requiring liquid-cooled racks and matching power redundancy, so a facility assessment should come first; second, SKU tier — NVL72/DGX configurations correspond to the peak tier of FP4 20 sparse, 15 dense PFLOPS, while the HGX B300 board has a reduced-power tier of FP4 18 sparse, 13.5 dense PFLOPS per GPU, so spell it out in the contract; third, form factor — NVLink's 1.8TB/s interconnect requires the SXM form factor and companion baseboard, and complete systems with a Grace CPU fall under the GB300 scope, a different procurement object from the single B300 card.